Review




Structured Review

A-M Systems monopolar suction electrode
Monopolar Suction Electrode, supplied by A-M Systems, used in various techniques. Bioz Stars score: 86/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/monopolar+suction+electrode/electrode+stimulating/bio_rxiv__2025__11__19__689305-45-76-79
Average 86 stars, based on 1 article reviews
monopolar suction electrode - by Bioz Stars, 2026-09
86/100 stars

Images

Related Articles

Isolation:

Article Title: Role of the postinspiratory complex in regulating swallow–breathing coordination and other laryngeal behaviors
Article Snippet: Continuing in the supine position, the occipital bone was removed, followed by continuous perfusion of the ventral medullary surface with warmed (~36°C) artificial cerebral spinal fluid (aCSF; in mM: 118 NaCl, 3 KCl, 25 NaHCO 3 , 1 NaH 2 PO 4 , 1 MgCl 2 , 1.5 CaCl 2 , 30 D-glucose) equilibrated with carbogen (95% O 2 , 5% CO 2 ) by a peristaltic pump (Dynamax RP-1, Rainin Instrument Co, Emeryville, CA). .. As previously published ( ; ), the XII and X nerves were isolated unilaterally, cut distally, and their activity was recorded from a fire-polished pulled borosilicate glass tip (B150-86-15, Sutter Instrument, Novato, CA) filled with aCSF connected to the monopolar suction electrode (A-M Systems, Sequim, WA) and held in a 3D micromanipulator (Narishige, Tokyo, Japan; ). .. Multiple bipolar EMGs, using 0.002′′ and 0.003′′ coated stainless steel wires (A-M Systems, part nos.

Article Title: Ndufs4 inactivation in glutamatergic neurons reveals swallow-breathing discoordination in a mouse model of Leigh syndrome.
Article Snippet: .. As previously published (Huff et al., 2022), the XII and X nerves were isolated unilaterally, cut distally, and their activity was recorded from a firepolished pulled borosilicate glass tip (B150–86-15, Sutter Instrument; Novato, CA, USA) filled with artificial cerebral spinal fluid (aCSF; in mM: 118 NaCl, 3 KCl, 25 NaHCO3, 1 NaH2PO4, 1 MgCl2, 1.5 CaCl2, 30 Dglucose) equilibrated with carbogen (95 % O2, 5 % CO2), connected to the monopolar suction electrode (A-M Systems, Sequim, WA, USA) and held in a 3D micromanipulator (Narishige, Tokyo, Japan). .. Multiple bipolar EMGs, using 0.002′′ and 0.003′′ coated stainless steel wires (A-M Systems, Sequim, WA, USA, part no.790600 and 791,000 respectively), simultaneously recorded activity from several swallow and respiratoryrelated muscle sites (Fig. 1).

Article Title: Ndufs4 inactivation in glutamatergic neurons reveals swallow-breathing discoordination in a mouse model of Leigh Syndrome
Article Snippet: .. As previously published ( ( )), the XII and X nerves were isolated unilaterally, cut distally, and their activity was recorded from a fire-polished pulled borosilicate glass tip (B150-86-15, Sutter Instrument; Novato, CA, USA) filled with artificial cerebral spinal fluid (aCSF; in mM: 118 NaCl, 3 KCl, 25 NaHCO 3 , 1 NaH 2 PO 4 , 1 MgCl 2 , 1.5 CaCl 2 , 30 D-glucose) equilibrated with carbogen (95% O 2 , 5% CO 2 ), connected to the monopolar suction electrode (A-M Systems, Sequim, WA, USA) and held in a 3D micromanipulator (Narishige, Tokyo, Japan). .. Multiple bipolar EMGs, using 0.002” and 0.003” coated stainless steel wires (A-M Systems, Sequim, WA, USA, part no.790600 and 791000 respectively), simultaneously recorded activity from several swallow and respiratory-related muscle sites.

Article Title: Mecp2 deficiency induces dysphagia in a preclinical model of Rett Syndrome
Article Snippet: .. The hypoglossal (XII) and vagus (X) nerves were isolated unilaterally, cut distally, and their activity was recorded from a fire-polished pulled borosilicate glass tip (1B150-4, WPI; Sarasota, FL, USA) filled with artificial cerebral spinal fluid (aCSF; in mM: 118 NaCl, 3 KCl, 25 NaHCO 3 , 1 NaH 2 PO 4 , 1 MgCl 2 , 1.5 CaCl 2 , 30 D-glucose) equilibrated with carbogen (95% O 2 , 5% CO 2 ), connected to the monopolar suction electrode (A-M Systems, Sequim, WA, USA) and held in a micromanipulator (KITE-R, WPI; Sarasota, FL, USA). .. Multiple bipolar EMGs, using 0.002” and 0.003” coated stainless steel wires (A-M Systems, Sequim, WA, USA, part no.790600 and 791000, respectively), were simultaneously recorded activity from several swallow and respiratory-related muscle sites.

Article Title: Postinspiratory complex acts as a gating mechanism regulating swallow-breathing coordination and other laryngeal behaviors
Article Snippet: The occipital bone was removed, followed by continuous perfusion of the medullary surface with warmed (~36°C) artificial cerebral spinal fluid (aCSF; in mM: 118 NaCl, 3 KCl, 25 NaHCO 3 , 1 NaH 2 PO 4 , 1 MgCl 2 , 1.5 CaCl 2 , 30 D-glucose) equilibrated with carbogen (95% O 2 , 5% CO 2 ) by a peristaltic pump (Dynamax RP-1, Rainin Instrument Co; Emeryville CA, USA). .. As previously published ( ( )), the XII and X nerves were isolated unilaterally, cut distally, and recorded from using a fire-polished pulled borosilicate glass (B150-86-15, Sutter Instrument; Novato, CA, USA) filled with aCSF connected to the monopolar suction electrode (A-M Systems, Sequim, WA, USA) and held in a 3D micromanipulator (Narishige, Tokyo, Japan). .. Multiple bipolar EMGs using 0.002” and 0.003” coated stainless steel wires (A-M Systems, Sequim, WA, USA, part no.790600 and 79100 respectively) according to the techniques of Basmajian and Stecko ( ) simultaneously recorded activity from several swallow- and respiratory-related muscle sites and were placed using hypodermic needles 30G (part no 305106, BD Precision Glide TM, Franklin Lakes, NJ, USA) in the: 1) submental complex , which consists of the geniohyoid, mylohyoid and digastric muscles, to determine swallow activity.

Article Title: Chronic intermittent hypoxia reveals role of the Postinspiratory Complex in the mediation of normal swallow production
Article Snippet: Continuing in the supine position, the occipital bone was removed, followed by continuous perfusion of the ventral medullary surface with warmed (~36°C) artificial cerebral spinal fluid (aCSF; in mM: 118 NaCl, 3 KCl, 25 NaHCO 3 , 1 NaH 2 PO 4 , 1 MgCl 2 , 1.5 CaCl 2 , 30 d -glucose) equilibrated with carbogen (95% O 2 , 5% CO 2 ) by a peristaltic pump (Dynamax RP-1, Rainin Instrument Co, Emeryville, CA). .. As previously published (Figure 6a in ), the XII and X nerves were isolated unilaterally, cut distally, and their activity was recorded from a fire-polished pulled borosilicate glass tip (B150-86-15, Sutter Instrument, Novato, CA) filled with aCSF connected to the monopolar suction electrode (A-M Systems, Sequim, WA) and held in a 3D micromanipulator (Narishige, Tokyo, Japan). .. Multiple bipolar EMGs, using 0.002′′ and 0.003′′ coated stainless steel wires (A-M Systems, part nos.

Activity Assay:

Article Title: Role of the postinspiratory complex in regulating swallow–breathing coordination and other laryngeal behaviors
Article Snippet: Continuing in the supine position, the occipital bone was removed, followed by continuous perfusion of the ventral medullary surface with warmed (~36°C) artificial cerebral spinal fluid (aCSF; in mM: 118 NaCl, 3 KCl, 25 NaHCO 3 , 1 NaH 2 PO 4 , 1 MgCl 2 , 1.5 CaCl 2 , 30 D-glucose) equilibrated with carbogen (95% O 2 , 5% CO 2 ) by a peristaltic pump (Dynamax RP-1, Rainin Instrument Co, Emeryville, CA). .. As previously published ( ; ), the XII and X nerves were isolated unilaterally, cut distally, and their activity was recorded from a fire-polished pulled borosilicate glass tip (B150-86-15, Sutter Instrument, Novato, CA) filled with aCSF connected to the monopolar suction electrode (A-M Systems, Sequim, WA) and held in a 3D micromanipulator (Narishige, Tokyo, Japan; ). .. Multiple bipolar EMGs, using 0.002′′ and 0.003′′ coated stainless steel wires (A-M Systems, part nos.

Article Title: Ndufs4 inactivation in glutamatergic neurons reveals swallow-breathing discoordination in a mouse model of Leigh syndrome.
Article Snippet: .. As previously published (Huff et al., 2022), the XII and X nerves were isolated unilaterally, cut distally, and their activity was recorded from a firepolished pulled borosilicate glass tip (B150–86-15, Sutter Instrument; Novato, CA, USA) filled with artificial cerebral spinal fluid (aCSF; in mM: 118 NaCl, 3 KCl, 25 NaHCO3, 1 NaH2PO4, 1 MgCl2, 1.5 CaCl2, 30 Dglucose) equilibrated with carbogen (95 % O2, 5 % CO2), connected to the monopolar suction electrode (A-M Systems, Sequim, WA, USA) and held in a 3D micromanipulator (Narishige, Tokyo, Japan). .. Multiple bipolar EMGs, using 0.002′′ and 0.003′′ coated stainless steel wires (A-M Systems, Sequim, WA, USA, part no.790600 and 791,000 respectively), simultaneously recorded activity from several swallow and respiratoryrelated muscle sites (Fig. 1).

Article Title: Network processes involved in the mediation of short-term habituation in Aplysia : contribution of intrinsic regulation of excitability and synaptic augmentation
Article Snippet: .. To measure siphon tap-evoked ULT sensory neuron activity, we obtained extracellular recordings en passant from the siphon nerve with a monopolar suction electrode (A-M Systems, Carlsborg, WA, USA) using techniques described in detail elsewhere ( ; ). ..

Article Title: Ndufs4 inactivation in glutamatergic neurons reveals swallow-breathing discoordination in a mouse model of Leigh Syndrome
Article Snippet: .. As previously published ( ( )), the XII and X nerves were isolated unilaterally, cut distally, and their activity was recorded from a fire-polished pulled borosilicate glass tip (B150-86-15, Sutter Instrument; Novato, CA, USA) filled with artificial cerebral spinal fluid (aCSF; in mM: 118 NaCl, 3 KCl, 25 NaHCO 3 , 1 NaH 2 PO 4 , 1 MgCl 2 , 1.5 CaCl 2 , 30 D-glucose) equilibrated with carbogen (95% O 2 , 5% CO 2 ), connected to the monopolar suction electrode (A-M Systems, Sequim, WA, USA) and held in a 3D micromanipulator (Narishige, Tokyo, Japan). .. Multiple bipolar EMGs, using 0.002” and 0.003” coated stainless steel wires (A-M Systems, Sequim, WA, USA, part no.790600 and 791000 respectively), simultaneously recorded activity from several swallow and respiratory-related muscle sites.

Article Title: Mecp2 deficiency induces dysphagia in a preclinical model of Rett Syndrome
Article Snippet: .. The hypoglossal (XII) and vagus (X) nerves were isolated unilaterally, cut distally, and their activity was recorded from a fire-polished pulled borosilicate glass tip (1B150-4, WPI; Sarasota, FL, USA) filled with artificial cerebral spinal fluid (aCSF; in mM: 118 NaCl, 3 KCl, 25 NaHCO 3 , 1 NaH 2 PO 4 , 1 MgCl 2 , 1.5 CaCl 2 , 30 D-glucose) equilibrated with carbogen (95% O 2 , 5% CO 2 ), connected to the monopolar suction electrode (A-M Systems, Sequim, WA, USA) and held in a micromanipulator (KITE-R, WPI; Sarasota, FL, USA). .. Multiple bipolar EMGs, using 0.002” and 0.003” coated stainless steel wires (A-M Systems, Sequim, WA, USA, part no.790600 and 791000, respectively), were simultaneously recorded activity from several swallow and respiratory-related muscle sites.

Article Title: Regulation of low-threshold afferent activity may contribute to short-term habituation in Aplysia californica.
Article Snippet: The goal of this study was to characterize the contribution of a population of low-threshold mechanoreceptors to short-term habituation of siphon-elicited reflex responses in Aplysia californica.. Since the location of their somata is unknown, we refer to them as the Unidentified Low-Threshold mechanoreceptors (ULTs).. The ULTs operate in parallel to the higher-threshold and well-characterized LE sensory neurons, yet little is known regarding their contribution to behavioral plasticity.

Article Title: Chronic intermittent hypoxia reveals role of the Postinspiratory Complex in the mediation of normal swallow production
Article Snippet: Continuing in the supine position, the occipital bone was removed, followed by continuous perfusion of the ventral medullary surface with warmed (~36°C) artificial cerebral spinal fluid (aCSF; in mM: 118 NaCl, 3 KCl, 25 NaHCO 3 , 1 NaH 2 PO 4 , 1 MgCl 2 , 1.5 CaCl 2 , 30 d -glucose) equilibrated with carbogen (95% O 2 , 5% CO 2 ) by a peristaltic pump (Dynamax RP-1, Rainin Instrument Co, Emeryville, CA). .. As previously published (Figure 6a in ), the XII and X nerves were isolated unilaterally, cut distally, and their activity was recorded from a fire-polished pulled borosilicate glass tip (B150-86-15, Sutter Instrument, Novato, CA) filled with aCSF connected to the monopolar suction electrode (A-M Systems, Sequim, WA) and held in a 3D micromanipulator (Narishige, Tokyo, Japan). .. Multiple bipolar EMGs, using 0.002′′ and 0.003′′ coated stainless steel wires (A-M Systems, part nos.



Similar Products

86
A-M Systems monopolar suction electrode
Monopolar Suction Electrode, supplied by A-M Systems, used in various techniques. Bioz Stars score: 86/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/monopolar+suction+electrode/electrode+stimulating/bio_rxiv__2025__11__19__689305-45-76-79
Average 86 stars, based on 1 article reviews
monopolar suction electrode - by Bioz Stars, 2026-09
86/100 stars
  Buy from Supplier

90
Hilgenberg gmbh monopolar suction electrodes realized by pulling tight-fitting glass pipettes
Monopolar Suction Electrodes Realized By Pulling Tight Fitting Glass Pipettes, supplied by Hilgenberg gmbh, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/monopolar+suction+electrode/monopolar+suction+electrodes+realized+by+pulling+tight+fitting+glass+pipettes/bio_rxiv__2024__07__15__603535-64-17-27
Average 90 stars, based on 1 article reviews
monopolar suction electrodes realized by pulling tight-fitting glass pipettes - by Bioz Stars, 2026-09
90/100 stars
  Buy from Supplier

90
Ethicon suction irrigator probe with an integrated monopolar electrode endopath® probe plus ii
Suction Irrigator Probe With An Integrated Monopolar Electrode Endopath® Probe Plus Ii, supplied by Ethicon, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/monopolar+suction+electrode/suction+irrigator+probe+with+an+integrated+monopolar+electrode+endopath++probe+plus+ii/pm23548802-28-10-17
Average 90 stars, based on 1 article reviews
suction irrigator probe with an integrated monopolar electrode endopath® probe plus ii - by Bioz Stars, 2026-09
90/100 stars
  Buy from Supplier

Image Search Results